INSTALLATION INSTRUCTIONS
Connecting dryer using 3-wire connection
If required, by local code, install external ground (not provided) to grounded metal, cold
water pipe, or other established ground determined by a qualified electrician.
L1
N
L2
Cover
Ground strap
3/4” Strain relief
and bracket
3 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit
marked for use with dryers and provided with closed loop or spade terminals with
upturned ends (not supplied)
3-wire connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit grounding through the neutral
conduction.
1
Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the
electrical box.
2
Be sure the dryer cord is unplugged from the wall receptacle.
3
Remove the power cord cover located at the upper back.
4
Install 3/4 in. UL-recognized strain relief to power cord entry hole. Bring power cord
through strain relief and bracket.
5
Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of the terminal block (marked N).
6
Be sure ground strap is connected to green ground screw on cabinet rear. Tighten all
terminal block screws (3) securely.
7
Properly secure power cord to strain relief and bracket.
8
Reinstall the cover.
IMPORTANT!
Never leave the cover off of the terminal block.