15
14a 15a
PULL THROUGH HOSES & MOVE INTO THE CAVITY SECURE THE DRAWER
As you push product in, pull through hoses and
cord, ensuring they don’t get kinked or twisted.
Important!
If product cannot be pushed in far enough, pull
out again and rearrange hoses and cord. Do not
use excessive force, as doing so may squash the
hoses and lead to incorrect operation.
Vent Hose
(Integrated
models only)
vent either
through
same cabinet
or adjacent
cabinet as per
step 9a or 9b
1
32
Open the
drawer halfway.
Using a flat-bladed
screwdriver, prize
the gray
rubber plug out
of the trim moulding.
Replace the gray
rubber plug back into
the trim moulding
and ensure the trim
seal is facing forward.
Repeat for all
four brackets.
Using a small Philips
screwdriver,
screw through the trim
moulding, securing the
side mounting bracket
to the cabinetry.
Do not damage the
rubber trimseal.
16a
INTEGRATED ONLY - SECURE THE EXTERNAL VENT
2
1
After routing the vent hose
through and out the hole
cutout, attach and secure the
vent by tightening the four
screws provided.
Airflow