59186 A 08.17INSTALLATION GUIDEUS CADD24DI, DD24DTI & DD24DHTI modelsDOUBLE DISHDRAWERTM DISHWASHER

Seite 2 - WARNING!

98 CAVITY PREPARATIONWater ConnectionRecommended HOT(Maximum 140°F/60°C).Supplied hose tosuit 3⁄8” (9 mm) malecompression fitting.Kosher requirementsD

Seite 3

109 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGELEFT HAND SIDE RIGHT HAND SIDEDrain hoses - 78 1/2” (2000mm)Drain hoses - 70 1/2” (1800mm)In

Seite 4 - 4” (100 mm)

11(x2)!0 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUIT

Seite 5

12213(x2)!2-A SECURE TO THE CABINETRY ON THE SIDES!4-A AFTER SECURING, REFER TO ‘FIT THE SUPPLIED TOEKICK PANEL’ STEP!3-A OPTIONALLY SECURE TO T

Seite 6

13(x2)!0 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVALAs you push product in, pull through hoses and cord, ensuring they don’t get kinked or twist

Seite 7

14x4(x2)!2-B SECURE TO THE CABINETRY ON THE SIDES !3-B OPTIONALLY SECURE TO THE CABINETRY ABOVESecure using two pairs of formed brackets. Repeat o

Seite 8

15!5 INSTALLING CUSTOM FRONT DRAWER PANELS112Electrical Shock HazardWARNING!Before continuing, ensure that the product is disconnected from the power

Seite 9 - (88mm - 100mm)

16!5 INSTALLING CUSTOM FRONT DRAWER PANELS2325/8” (16mm)(x6)41125/8” (16mm) (x3)!5-C ATTACH CUSTOM PANELS TO PANEL BRACKETSThere must be at least3 s

Seite 10 - 8 CAVITY PREPARATION

17!5 INSTALLING CUSTOM FRONT DRAWER PANELS!5-E CONNECT THE KNOCK-TO-PAUSE MODULE TO THE CONTROLLER!5-G ATTACH CUSTOM PANELS TO PRODUCT!5-F RECONN

Seite 11

18!6 FITTING A CUSTOM TOEKICK PANELPROFILE APROFILE B9Custom Toekick PanelToekick mounting bracket cutting templateCustom toekick panelToekick mountin

Seite 12

11 SAFETY AND WARNINGS WARNING!Electrical Shock HazardWARNING: To reduce the risk of electrical shock, fire, or injury to persons, the installer mus

Seite 13

19!6 FIT THE SUPPLIED PREFINISHED TOEKICK PANEL (IF PREFERRED)1234191956897IMPORTANT!Do not overtighten screw.Slide the toekick onto the mounting rail

Seite 14 - 4” (100mm)

2012!7 THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE.DRAINAGE OPTION 1Dishwasher and Ø 1 1/2” (38 mm) Standpi

Seite 15

21min. R 8” (200 mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 2Dishwasher using Air Break wit

Seite 16 - WARNING!

22123min. R 8” (200 mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 3Dishwasher using drain hose

Seite 17 - TO CUSTOM PANELS

23Ensure the supplied rubber washer is fitted inside the coupling.Tighten coupling with spanner.180oNo leaks!12@0 TROUBLESHOOTING ●Excessive water rem

Seite 18 - IMPORTANT!

24@1 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLERComplete and keep for safe reference:Model Serial No. Purchase Date Purchaser Dealer Address I

Seite 19

59186 A 08.17INSTALLATION GUIDEUS CADD24SI, DD24STI & DD24SHTI modelsSINGLE DISHDRAWERTM DISHWASHER

Seite 20

11 SAFETY AND WARNINGS WARNING!Electrical Shock HazardWARNING: To reduce the risk of electrical shock, fire, or injury to persons, the installer mus

Seite 21

22 PARTS SUPPLIEDClamp (1)(for securing Drain hose joiner)Wire clip (1) (for securing Drain hose joiner)Phillips 16 mm screws (7)38 mmbottom fixing

Seite 22

33 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION3-A REMOVE THE DRAWER 3-B REMOVE THE ACCESS COVER & REMOVE POWER Access coverClipClipElectron

Seite 23

22 PARTS SUPPLIEDIf the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which wi

Seite 24 - @0 TROUBLESHOOTING

43 OPTIONALLY HARD WIRING PRIOR TO INSTALLATIONIMPORTANT!Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics

Seite 25 - @1 FINAL CHECKLIST

54 PRODUCT DIMENSIONSDD24SIDD24STIDD24SHTIPRODUCT DIMENSIONS INCHES (MM) INCHES (MM)AOverall height of product 116 1/8” (410) min. 17 7/8” (454)

Seite 26 - SINGLE DISHDRAWER

65 CABINETRY DIMENSIONSDD24SIDD24STIDD24SHTICABINETRY DIMENSIONS INCHES (MM) INCHES (MM)JInside height of cavitymin. 16 1/4” (412) min. 18” (4

Seite 27

76 CUSTOM DRAWER PANEL SPECIFICATIONSThe following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry.

Seite 28 - 2 PARTS SUPPLIED

87 CAVITY PREPARATIONWater ConnectionRecommended HOT (Maximum 140°F/60°C).Supplied hose to suit 3/8” (9 mm) male Water Pressure Water softener modelsM

Seite 29

9ø 2 3⁄8” (60mm)ø 2 3⁄8” (60mm)ø 2 3⁄8” (60mm)ø max. 1 1⁄2” (38mm)ø max. 1 1⁄2” (38mm)ø 2 3⁄8” (60mm)max. 3⁄16” (5mm)max. 3⁄16” (5mm)8 11⁄16” (220mm)8

Seite 30

109 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE!0 TALL HEIGHT INTEGRATED MODELS FOR 18 7⁄8” (480MM) CAVITY ONLY - ATTACH CAVITY BRACKETLEFT

Seite 31 - 4 PRODUCT DIMENSIONS

11!1 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE

Seite 32 - 5 CABINETRY DIMENSIONS

12As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted. IMPORTANT!If product cannot be pushed in far enough,

Seite 33 - - 2x =

13!1 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL!1-A ATTACH VENTING HOSEFitted ElbowCheck that the fitted elbow is rotated left or right (depe

Seite 34 - 7 CAVITY PREPARATION

33 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION3-A REMOVE THE LOWER DRAWER 3-B REMOVE THE ACCESS COVER & REMOVE POWER Access coverClipClipEl

Seite 35

1421344!3-B REMOVE THE DRAWER !4-B SECURE TO THE CABINETRY ON THE SIDES4” (100mm)To prevent kinked hosesEither sit the drawer down on the left han

Seite 36

1512344” (100mm)!5-B REFIT THE DRAWER ONTO THE RUNNERS!6-B SECURE THE EXTERNAL VENTBefore refitting the drawer, ensure the hoses are not twisted a

Seite 37 - Clip all four side mounting

16!7 INSTALLING A CUSTOM FRONT DRAWER PANEL112Electrical Shock HazardWARNING!Before continuing, ensure that the product is disconnected from the power

Seite 38 - -A SECURE THE EXTERNAL VENT

172316mm (x6)!7 INSTALLING CUSTOM FRONT DRAWER PANELS1216mm (x3)!7-C ATTACH CUSTOM PANELS TO PANEL BRACKETSThere must be at least3 screws used each

Seite 39 - !1-A ATTACH VENTING HOSE

18!7 INSTALLING CUSTOM FRONT DRAWER PANELS!7-E CONNECT THE KNOCK-TO-PAUSE MODULE TO THE CONTROLLER!7-G ATTACH CUSTOM PANEL TO PRODUCT!7-F RECONN

Seite 40

1912!8 THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE.DRAINAGE OPTION 1Dishwasher and Ø 1 1/2” (38 mm) Standpi

Seite 41 - -B SECURE THE EXTERNAL VENT

2012min. R 8” (200mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 2Dishwasher using Air Break wi

Seite 42

21312min. R 8” (200mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 3Dishwasher using drain hose

Seite 43 - TO CUSTOM PANEL

22Ensure the supplied rubber washer is fitted inside the coupling.Tighten coupling with spanner.180oNo leaks!12!9 CONNECT INLET HOSE TO HOT WATER @0

Seite 44

23@1 TROUBLESHOOTING ●Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How

Seite 45

43 OPTIONALLY HARD WIRING PRIOR TO INSTALLATIONIMPORTANT!Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics

Seite 46

24@2 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLERComplete and keep for safe reference:Model Serial No. Purchase Date Purchaser Dealer Address I

Seite 49 - @1 TROUBLESHOOTING

54 PRODUCT DIMENSIONSSTANDARDHEIGHTMODELSTALLHEIGHTMODELSPLANPROFILEFRONTDD24DIDD24DTIDD24DHTIPRODUCT DIMENSIONS INCHES (MM) INCHES (MM)AOverall

Seite 50 - @2 FINAL CHECKLIST

65 CABINETRY DIMENSIONSMinimum clearances from adjacent cabinetrySTANDARDHEIGHTMODELSTALLHEIGHTMODELSDD24DIDD24DTIDD24DHTICABINETRY DIMENSIONS INC

Seite 51

76 CUSTOM DRAWER PANEL SPECIFICATIONSThe following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry.

Seite 52

87 CUSTOM TOEKICK PANEL SPECIFICATIONSHEIGHT OF THE TOEKICK PANELMeasure D (height from the top of adjacent cabinet door fronts to the floor) and wr

Kommentare zu diesen Handbüchern

Keine Kommentare